Formulator™, Regulator™, & Integrator™ are registered trademarks of Formulator Software LLC. All other manufacturers’ trademarks acknowledged.
 CAS® is a registered trademark of the American Chemical Society. Copyright © 2007 Formulator Software LLC.  All rights reserved.

Cosmetics 
& Drug OTC  Version

Get Information,
Quotes & Free
Trial Version

Price List for Formulator & Regulator

REGULATOR MSDS Software

INTEGRATOR
Data Exchange Software

INVENTORY MANAGER 

QUALITY 
MANAGER

PRODUCTION 
MANAGER

FORMULATOR
LAB-BOOK


A Dynamic Windows Software Program for the Formulating
Cosmetic & Drug-OTC Chemist


What is the FORMULATOR
Cosmetics & Drug-OTC Version?

  • FORMULATOR™is a Windows software program written for the Formulation Chemist. It provides a dynamic set of calculation and data manipulation tools to aid in the development and testing of new batch formulas, testing of new materials and improvement of current formula performance. The data can be integrated with most transactional ERP programs utilizing ODBC databases. The Cosmetic & DrugOTC Version of FORMULATOR supplies all of the dynamic basic formulating tools and adds Product Formulation and Product Label development features needed by Cosmetic Chemists and Drug OTC Formulators. supplies all of the dynamic basic formulating tools and adds Product Formulation and Product Label development features needed by Cosmetic Chemists and Drug OTC Formulators. FORMULATOR Complies with 21 CFR Part 11 FDA requirements.

 

  • All of the software features and functions to build formulas by % weight, Quantity Sufficient, or by actual units of measure in weight and/or volume.
  • Tools to develop product label logic; fetches and displays stored product information and ingredients with or without % amount with the ability to add warning or usage statements.
  • Quality Control Method & Procedure Creation and Control with test results captured as you test and modify the formulation.
  • Costing analysis, raw materials as you build the formula - automatically - by the gram, ounce or any weight or volume measure, any time, anywhere in the formulating program.
  • Full costing with added packaging bills of materials, overhead and labor added to materials cost by selected unit of measure of package fill amount.
  • Define your own properties, instructions, and units of measure.
  • Formula Performance Calculations based on all available user-defined Properties.
  • Formula Tree Viewers with multiple formula windows, allows cut/copy and paste from one formula to another, with explosion of intermediate materials into their component raw materials.
  • Complies with 21 CFR 11 FDA electronic record requirements.
 

Why Consider FORMULATOR Cosmetics & Drug-OTC?

  •  All of the latest precision calculating and data handling tools.
  •  Speed formula development, modification and improvement.
  •  Low cost, makes it easy to own.
  • See the explosion of Intermediates at multi-level, as well as the Sum of Components of a full formula and side by side formula components.
  • Fully ANSI SQL compatible ODBC data connectivity allows data sharing as you build your database of materials, properties, formulas, testing procedures and test and performance results.
  • Latest Windows graphic tools make it easy to learn, easy to use, easy to train others.
  • Can be used as a QC test result archive for standard production when integrated with Quality Manager.
  •  Integrates with REGULATOR™ for MSDS development and output including INCI name option.
  •  Itegrates with most ERP Manufacturing data bases using INTEGRATOR development tools
  • Available with Microsoft Access or Microsoft SQL databases. Operates in standard Windows Networks and standalone computers.
  •  Best of all, you can try it before you buy. 

 

System Functions

 

FORMULATOR™  is supplied with all of the tools to develop your materials data base, build the properties files, create performance equations (standard equations are supplied with the program), enhance weight and volume conversions to be used at all levels of calculation, document your quality control tests and make them part of the formula development and testing documentation. User functions can be set by the primary user to limit changes to critical functions.

 

Development Screens

These screens are the main working modules for formula development and automatic calculation of formula performance. Performance calculations are based on user developed and modified calculation logic.

Quantity Sufficient formulation development. This feature allows a user to define a base material as Quantity Sufficient (QS). That material is then 100%. (This could be an intermediate mixture or a single raw material). As other materials are added on a weight % basis the amount is reduced in the QS material. The other materials remain at their fixed % as new materials are added on a % basis and deduct automatically from the QS material %. The user can switch to actual count or straight % formulation techniques at any time and switch between methods.

 

  Label Development

 

Cosmetic and DrugOTC Product Label Design - Similar in some ways to our Nutritional Label section FORMULATOR'S Nutritional Version, these tools allow the Cosmetic Chemist and Drug Developer to create the basic information for a Cosmetic Label including 3 sections: Section 1 for Product Name, Description, Company Name and other identifiers. Section 2 to define claims, directions or warnings. Section 3 to do ingredient list, either INCI names listed high to low, or INCI names with a list of Active Ingredients, high to low with % weight, and Inert Ingredients, high to low with % weight. The user can edit all 3 sections. Bar Codes, fill amount and other information can also be added.


Signature Pad Functionality


FORMULATOR now supports user signature capture on additions or changes to formulations.  This capability is available universally or selectively through FORMULATOR'S formula groups capability.  Also available for Batch Approvals in Quality Manager and Project Approvals in Project Manager.

When a formula group is designated as requiring a signature, any changes to a formula with that group will prompt for a signature from the user.  The signature is then stored along with the formula, and will be visible as an image when the formula change log is displayed.  All signatures are stored in the main FORMULATOR database.      

Alternately, FORMULATOR can require a signature for all formula changes, regardless of the formula group. FORMULATOR supports Interlink Electronics ePad signature pads.  If signature capture is installed, any PC that needs to save formula changes will require one.  Contact sales@formulatorus.com for availability and pricing.

Using the ePad™ Signature Pad 

The Interlink ePad plugs into any USB port on your computer. The drivers required are included with the ePad  and are activated by the FORMULATOR license file. Click HERE to view how to install the drivers.

Once installed selection of signature approval areas is done in the Company Setup options epad tab.

Get Information,
Quotes & Free
Trial Version

Price List for Formulator & Regulator

REGULATOR MSDS Software

INTEGRATOR
Data Exchange Software

INVENTORY MANAGER 

QUALITY 
MANAGER

PRODUCTION 
MANAGER

FORMULATOR
LAB-BOOK

Formulator™, Regulator™, & Integrator™ are registered trademarks of Formulator Software LLC. All other manufacturers’ trademarks acknowledged.
 CAS® is a registered trademark of the American Chemical Society. Copyright © 2007 Formulator Software LLC.  All rights reserved.

28 Center Street · Clinton, NJ 08809 
 (908) 735-2248   · (908) 236-7865 FAX
EMAIL: sales@formulatorus.com

WWW.COLOR-TEC.COM
Color Instruments & Software
Batch Manufacturing Software
Learn About Color